Emittance growth from three-dimensional coherent synchrotron radiation in compressors · revision history
Revision 2
Accepted · core change · record
Changes against revision 1:
- Title
- Emittance growth from three-dimensional coherent synchrotron radiation in compressors
- Plain
- Standard models treat the bunch as a thin line, which fails for bunches that are wide compared with their length; the blow-up of such wide, compressed bunches is not reliably predicted.
- Precise · changed · core
- Revision 1: The 1D steady-state CSR wake for a bunch of rms length $\sigma_z$ on a bend of radius $R$ is valid when the transverse size satisfies $\sigma_x << (\sigma_z^2 R)^{1/3}$. For magnetic bunch compressors where this inequality fails ($\sigma_z \sim 1e-4$ to 1e-3 cm, 1e8 to 1e10 electrons per bunch), compute projected and slice emittance growth including the transverse variation of the radiation field, transient fields at magnet entrance and exit, and vacuum-chamber shielding, and state the parameter region in which the 1D model errs by more than a factor 2.
- Revision 2: The 1D steady-state CSR wake for a bunch of rms length $\sigma_z$ on a bend of radius $R$ is valid when the transverse size satisfies $\sigma_x << (\sigma_z^2 R)^{1/3}$. For magnetic bunch compressors where this inequality fails ($\sigma_z \sim 10^{-4}$ to $10^{-3}$ cm, $10^{8}$ to $10^{10}$ electrons per bunch), compute projected and slice emittance growth including the transverse variation of the radiation field, transient fields at magnet entrance and exit, and vacuum-chamber shielding, and state the parameter region in which the 1D model errs by more than a factor 2.
- Settled by
- Self-consistent 3D field calculations benchmarked against slice-emittance measurements downstream of a chicane scanned across $\sigma_x \sim (\sigma_z^2 R)^{1/3}$.
- Kind
- well-posed
- Answer type
- value
- References
- (empty)
- Literature status
- partially-resolved
- Status note
- 3D CSR codes have been developed since the 2000s, but measured benchmarks in the regime where the 1D model fails remain few (2024-2026 literature not checked in detail).
- Posed since
- (empty)
Decisions
- Accept · 2026-10-15 · record