What causes the bulk ionization excess in DAMIC CCDs at SNOLAB?
Plain
Silicon camera chips used to search for dark matter deep underground see extra small charge signals from inside the silicon, beyond all known radioactivity. The cause is unknown.
Precise
DAMIC at SNOLAB reported an excess of bulk ionization events above the radiogenic background model, with characteristic rate about 7 events/(kg day) at electron-equivalent energies about 80 eV, later confirmed with skipper CCDs. An answer identifies the source (unmodeled background such as low-energy Compton or surface events, a detector effect, or new physics) and predicts the rate and spectrum in other silicon detectors.
Settled by
Comparison of the bulk excess across silicon CCDs with different fabrication, depth, shielding and cosmogenic exposure (DAMIC-M, SENSEI, Oscura prototypes) and with calibrated low-energy Compton spectra.
Kind
phenomenon
Answer type
identification
References
(empty)
Literature status
open
Status note
Confirmed with skipper CCDs at SNOLAB (Phys. Rev. D 109, 062007, 2024, arXiv 2306.01717); origin unknown.
Posed since
2020