- Value of the dose and dose-rate effectiveness factor
- Plain
- Risk estimates from survivors of single sudden exposures are scaled down before being applied to slow exposures. The scaling number is chosen by committee rather than measured.
- Precise
- Determine the dose and dose-rate effectiveness factor, the ratio of risk per unit dose at high acute dose rate to that at protracted low dose rate, for solid cancer and for leukaemia separately. Values in use range from 1 to 2 (the ICRP uses 2, some bodies use 1). An answer is a measured value with uncertainty, per endpoint.
- Settled by
- Direct comparison of risk coefficients between acutely exposed and chronically exposed cohorts with comparable dosimetry quality.
- Kind
- well-posed
- Answer type
- value
- References
- (empty)
- Literature status
- contested
- Status note
- Protracted-exposure cohorts reported risk coefficients comparable to acute ones, which would imply a factor near 1, against the protection value of 2.
- Posed since
- 1980