All problems
65 problems
Starting order drafted by AI. Votes change it. How ranking works
-
Beam-quality factors and $W_{\mathrm{air}}$ for ion dosimetry
Partially resolved 36Reduce the uncertainty in the mean energy per ion pair in air $W_{\mathrm{air}}$ and in the beam-quality correction factor $k_Q$ for carbon and other ions to the level needed for a total dosimetric uncertainty below $1.5\%$. ICRU 90 values are $W_{\mathrm{air}}$ of about $34.44\,\mathrm{eV}$ for protons (about $0.4\%$ standard uncertainty) and $34.71\,\mathrm{eV}$ for carbon ions (about $1.5\%$). An answer is a measured value set with reduced uncertainty.
-
Structural universality class from time-dependent diffusion
Partially resolved 36For the diffusion coefficient $D(t)$ in tissue approaching its long-time value as $D(t) - D_{\infty} \sim t^{-\theta}$, with $\theta = (p + d)/2$ where d is the spatial dimension of the relevant disorder and p the structural exponent of its density correlations at long wavelengths, measure $\theta$ and assign p for white matter along and across axons, grey matter and muscle. An answer is a classification of tissues by p with measured exponents and uncertainty.
-
Determine the yield and energy spectrum of electrons below 1 keV escaping a gold nanoparticle of 2 to 100 nm diameter per absorbed photon of 20 to 150 keV, including Auger and Coster-Kronig cascades (chains of atomic relaxations that each eject an electron), solid-state and plasmon effects, and self-absorption inside the particle, to an accuracy of about 20 percent. An answer is a measured and computed emission spectrum that reconciles the transport codes and gives the radial dose profile within 1 micron of the particle.
-
Fundamental bound on scintillation timing
Partially resolved 34Derive the Cramer-Rao lower bound (the minimum variance any unbiased estimator can reach) on timing precision for a scintillation detector including non-exponential rise and decay, position-dependent light transport inside the crystal, photodetector single-photon time response and dark counts, and construct an estimator reaching it. An answer is the bound as a function of photon yield, rise time, decay time and transit-time spread, plus a realizable estimator.
-
Optimal energy thresholds for material separation
Partially resolved 28Determine the energy threshold set that minimizes the variance of material-decomposition estimates for a given task, tube spectrum, patient thickness and dose, including the detector response with charge sharing and pileup. Compare against the Cramer-Rao bound (the minimum variance any unbiased estimator can reach) achievable with full spectral information. An answer is an optimization rule plus the efficiency loss from using 2 to 8 bins.